Solar Pump Sizing: Depth and Litres Decide, Not Horsepower
"A 100-metre borehole does not automatically require a 2HP pump" — the forum warning that saves $10,000 wells. Here's the 5-minute version.
The two numbers that decide everything
- Total dynamic head = borehole depth to water + drawdown + height to tank. Not the drilled depth — the water level.
- Daily litres = people, livestock, fish ponds or irrigation. A fish pond turnover is a different game from a family of six.
- Pump power follows head × flow. An oversized pump burns money at purchase and watts every sunny hour; an undersized one dies young.
Rough guide (DC solar pumps, 4–5 peak sun hours)
| Head (water depth) | Family / small garden | Livestock + garden | Fish pond turnover |
|---|---|---|---|
| 20–40m | 500W DC pump | 750–1000W | 1500W+ |
| 60–100m | 750–1100W | 1500–2200W | 3000W |
| 100–140m | 1500–2200W | 3000W | consult us |
The protections that decide whether the well survives
- Dry-run protection is non-negotiable: if water level drops below the intake, an unprotected motor burns in minutes — and a $200 pump kills a $10,000 borehole.
- AC/DC dual input keeps water flowing on grid or generator evenings, not just sun.
- A float switch or tank-full sensor beats a forgetful human every single day.
Free sizing — send three numbers
Borehole depth, water level (or 'unknown'), and litres per day you need. We return the pump model, flow/head curve and an itemized quote. Free, one hour.
Frequently asked
What if I don't know my water level?
Send the drilled depth and we'll size with a conservative drawdown assumption, then confirm on install day with a simple dip measurement — two minutes with a weighted line.
Solar or grid pump?
Solar for daytime demand (irrigation, livestock, pond turnover); hybrid AC/DC if you need evening water too. We ship both, and the hybrid costs less than a generator conversion.
Can a pump run directly from panels without a battery?
Yes — that is the standard solar pump design. Batteries exist for the inverter, not the pump. Direct-drive is cheaper and the pump simply produces less water on cloudy hours, which tanks buffer.